How the poles of a filter generate its impulse response

Consider a 2-pole filter with an impulse response given by:

(1)   \begin{equation*} h[n] = 2\rho^n\cos(\wh_0 n)\,u[n] = \big(\rho e^{i \hat{\omega}_0}\big)^n u[n] + \big(\rho e^{-i \hat{\omega}_0}\big)^n u[n] . \end{equation*}

where \rho and \hat{\omega}_0 are positive real constants.

The impulse response of this filter (indeed, any filter with real coefficients) is a weighted sum of the signals generated by its conjugate poles. For each conjugate pole pair, the angle \pm\hat{\omega}_0 sets the frequency at which the filter “rings”, and the distance from the origin \rho sets how quickly that ringing decays (or grows).

The zeros play a different role. They don’t change which signals contribute to h[n], but rather they set how much of each is included. Moving the zeros of this filter would change the amplitude of the ringing, and where in its cycle it starts, but not its frequency or how quickly it decays.